IECC CLIMATE ZONE 5A // Cool · Humid
Climate Zone 5A Insulation R-Values, Window U-Factor & SHGC Requirements
Side-by-side IECC 2021 vs 2024 residential REScheck and commercial COMcheck thermal envelope specifications for Climate Zone 5A (Chicago, IL, Boston, MA, Detroit, MI, Columbus, OH, Pittsburgh, PA).
| Assembly Component | 2021 IECC Residential | 2024 IECC Residential | 2021 COMcheck (Com) | 2024 COMcheck (Com) |
|---|---|---|---|---|
| Fenestration Max U-Factor | 0.30 | 0.29 | 0.36 | 0.35 |
| Glazing Max SHGC | NR (N/A) | NR (N/A) | 0.38 | 0.38 |
| Ceiling / Roof R-Value (Max U) | R-60 (0.0240) | R-60 (0.0230) | R-30ci (above deck) (0.0320) | R-30ci (above deck) (0.0307) |
| Exterior Wall R-Value (Max U) | R-20+5ci or R-13+10ci (0.0450) | R-20+5ci or R-13+10ci (0.0432) | R-13 + 10ci (steel) (0.0550) | R-13 + 10ci (steel) (0.0528) |
| Floor Insulation (Max U) | R-30 (0.0330) | R-30 (0.0317) | U ≤ 0.0520 | U ≤ 0.0499 |
| Basement Wall R-Value | R-15ci or R-19 | R-15ci or R-19 | C402 Below-Grade | C402 Below-Grade |
| Slab Edge R-Value (Max F) | R-10ci (4 ft) (F ≤ 0.51) | R-10ci (4 ft) (F ≤ 0.51) | F ≤ 0.51 | F ≤ 0.51 |
| Opaque Door Max U-Factor | 0.30 | 0.29 | 0.37 | 0.35 |
Heating-dominated cool-humid: Residential SHGC is NR (N/A); commercial max SHGC 0.38.
US States Containing IECC Climate Zone 5A (19)
Connecticut (CT)
2021 IECC (2022 CT State Building Code)
Illinois (IL)
2021 IECC (Illinois Energy Conservation Code)
Indiana (IN)
2020 Indiana Residential Code (2018/2009 IECC hybrid)
Iowa (IA)
2012 / 2015 IECC (State Energy Code)
Kansas (KS)
2018 / 2021 IECC (Local AHJ Adoption)
Maryland (MD)
2021 IECC (Maryland Building Performance Standards)
Massachusetts (MA)
2021 IECC / MA Stretch & Specialized Opt-in Code
Michigan (MI)
2015 / 2021 IECC (Michigan Energy Code)
Missouri (MO)
2018 / 2021 IECC (Home Rule AHJs)
Nebraska (NE)
2018 IECC (Nebraska Energy Code)
New Hampshire (NH)
2018 IECC (NH State Building Code)
New Jersey (NJ)
2021 IECC (NJ Uniform Construction Code)
New York (NY)
2020 NYECC / NYCECC (NYStretch Ready)
North Carolina (NC)
2018 NC Energy Conservation Code (2015/2018 IECC)
Ohio (OH)
2019 Residential Code of Ohio (2018 IECC)
Pennsylvania (PA)
2018 IECC (PA UCC; Philadelphia 2021 IECC)
Rhode Island (RI)
2021 / 2024 IECC (RI State Energy Conservation Code)
South Dakota (SD)
2018 / 2021 IECC (Local AHJ Adoption)
West Virginia (WV)
2015 / 2018 IECC (WV State Building Code)
Permit & Energy Code FAQ
What are the residential wall and ceiling R-Values for IECC Climate Zone 5A?
Under 2021 IECC in Climate Zone 5A, prescriptive residential ceilings require R-60 (max U 0.0240) and wood-framed exterior walls require R-20+5ci or R-13+10ci (max U 0.0450).
What is the maximum window U-Factor and SHGC in Climate Zone 5A?
For residential construction under 2021 IECC, Zone 5A requires fenestration U-Factor <= 0.30 (tightening to 0.29 under 2024 IECC modeling) with SHGC NR (N/A). Heating-dominated cool-humid: Residential SHGC is NR (N/A); commercial max SHGC 0.38.
How does commercial COMcheck differ from residential REScheck in Zone 5A?
Commercial buildings in Zone 5A use steel-framed/mass wall and above-deck roof assemblies (window U <= 0.36, SHGC <= 0.38, roof R-30ci (above deck), wall R-13 + 10ci (steel)) and cap prescriptive Window-to-Wall Ratio at 30%.
Explore All 15 IECC Climate Zones
Verify Your Climate Zone 5A Blueprints in Minutes
Upload permit PDFs or CSV schedules to calculate net wall areas, check Zone 5A U-Factor & SHGC compliance, and export DOE REScheck (.rck) or PNNL COMcheck payloads.