IECC CLIMATE ZONE 2B // Hot · Dry
Climate Zone 2B Insulation R-Values, Window U-Factor & SHGC Requirements
Side-by-side IECC 2021 vs 2024 residential REScheck and commercial COMcheck thermal envelope specifications for Climate Zone 2B (Phoenix, AZ, Tucson, AZ, Yuma, AZ, Imperial, CA).
| Assembly Component | 2021 IECC Residential | 2024 IECC Residential | 2021 COMcheck (Com) | 2024 COMcheck (Com) |
|---|---|---|---|---|
| Fenestration Max U-Factor | 0.40 | 0.38 | 0.45 | 0.43 |
| Glazing Max SHGC | 0.25 | 0.25 | 0.25 | 0.25 |
| Ceiling / Roof R-Value (Max U) | R-49 (0.0260) | R-49 (0.0250) | R-25ci (above deck) (0.0390) | R-25ci (above deck) (0.0374) |
| Exterior Wall R-Value (Max U) | R-13+0 (0.0840) | R-13+0 (0.0806) | R-13 + 3.8ci (steel) (0.0840) | R-13 + 3.8ci (steel) (0.0806) |
| Floor Insulation (Max U) | R-13 (0.0640) | R-13 (0.0614) | U ≤ 0.0740 | U ≤ 0.0710 |
| Basement Wall R-Value | R-0 (NR) | R-0 (NR) | C402 Below-Grade | C402 Below-Grade |
| Slab Edge R-Value (Max F) | R-0 (NR) (F ≤ 0.73) | R-0 (NR) (F ≤ 0.73) | F ≤ 0.73 | F ≤ 0.73 |
| Opaque Door Max U-Factor | 0.40 | 0.38 | 0.61 | 0.59 |
Desert cooling loads make SHGC <= 0.25 the single highest-impact glazing specification.
US States Containing IECC Climate Zone 2B (3)
Permit & Energy Code FAQ
What are the residential wall and ceiling R-Values for IECC Climate Zone 2B?
Under 2021 IECC in Climate Zone 2B, prescriptive residential ceilings require R-49 (max U 0.0260) and wood-framed exterior walls require R-13+0 (max U 0.0840).
What is the maximum window U-Factor and SHGC in Climate Zone 2B?
For residential construction under 2021 IECC, Zone 2B requires fenestration U-Factor <= 0.40 (tightening to 0.38 under 2024 IECC modeling) with SHGC 0.25. Desert cooling loads make SHGC <= 0.25 the single highest-impact glazing specification.
How does commercial COMcheck differ from residential REScheck in Zone 2B?
Commercial buildings in Zone 2B use steel-framed/mass wall and above-deck roof assemblies (window U <= 0.45, SHGC <= 0.25, roof R-25ci (above deck), wall R-13 + 3.8ci (steel)) and cap prescriptive Window-to-Wall Ratio at 30%.