IECC CLIMATE ZONE 4A // Mixed · Humid
Climate Zone 4A Insulation R-Values, Window U-Factor & SHGC Requirements
Side-by-side IECC 2021 vs 2024 residential REScheck and commercial COMcheck thermal envelope specifications for Climate Zone 4A (New York, NY, Washington, DC, Philadelphia, PA, Nashville, TN, Kansas City, MO).
| Assembly Component | 2021 IECC Residential | 2024 IECC Residential | 2021 COMcheck (Com) | 2024 COMcheck (Com) |
|---|---|---|---|---|
| Fenestration Max U-Factor | 0.30 | 0.29 | 0.36 | 0.35 |
| Glazing Max SHGC | NR (N/A) | NR (N/A) | 0.36 | 0.36 |
| Ceiling / Roof R-Value (Max U) | R-60 (0.0240) | R-60 (0.0230) | R-30ci (above deck) (0.0320) | R-30ci (above deck) (0.0307) |
| Exterior Wall R-Value (Max U) | R-20+5ci or R-13+10ci (0.0450) | R-20+5ci or R-13+10ci (0.0432) | R-13 + 7.5ci (steel) (0.0640) | R-13 + 7.5ci (steel) (0.0614) |
| Floor Insulation (Max U) | R-19 (0.0470) | R-19 (0.0451) | U ≤ 0.0520 | U ≤ 0.0499 |
| Basement Wall R-Value | R-10ci or R-13 | R-10ci or R-13 | C402 Below-Grade | C402 Below-Grade |
| Slab Edge R-Value (Max F) | R-10ci (4 ft) (F ≤ 0.52) | R-10ci (4 ft) (F ≤ 0.52) | F ≤ 0.52 | F ≤ 0.52 |
| Opaque Door Max U-Factor | 0.30 | 0.29 | 0.37 | 0.35 |
NR in EnvelopeCheck residential UA engine (prescriptive IECC 2021 Table R402.1.3 lists 0.40 for 4A; 0.36 commercial).
US States Containing IECC Climate Zone 4A (19)
Arkansas (AR)
2014 Arkansas Energy Code (2009/2015 IECC base)
Delaware (DE)
2021 IECC (State Energy Code)
District of Columbia (DC)
2021 IECC / DC Energy Conservation Code
Georgia (GA)
2015 IECC (Georgia State Supplements)
Illinois (IL)
2021 IECC (Illinois Energy Conservation Code)
Indiana (IN)
2020 Indiana Residential Code (2018/2009 IECC hybrid)
Kansas (KS)
2018 / 2021 IECC (Local AHJ Adoption)
Kentucky (KY)
2018 Kentucky Residential Code (2012/2018 IECC)
Maryland (MD)
2021 IECC (Maryland Building Performance Standards)
Missouri (MO)
2018 / 2021 IECC (Home Rule AHJs)
New Jersey (NJ)
2021 IECC (NJ Uniform Construction Code)
New York (NY)
2020 NYECC / NYCECC (NYStretch Ready)
North Carolina (NC)
2018 NC Energy Conservation Code (2015/2018 IECC)
Ohio (OH)
2019 Residential Code of Ohio (2018 IECC)
Oklahoma (OK)
2018 IRC / IECC (Oklahoma OUBCC Amended)
Pennsylvania (PA)
2018 IECC (PA UCC; Philadelphia 2021 IECC)
Tennessee (TN)
2018 IECC (Tennessee State Amended)
Virginia (VA)
2021 Virginia Energy Conservation Code (2021 IECC Amended)
West Virginia (WV)
2015 / 2018 IECC (WV State Building Code)
Permit & Energy Code FAQ
What are the residential wall and ceiling R-Values for IECC Climate Zone 4A?
Under 2021 IECC in Climate Zone 4A, prescriptive residential ceilings require R-60 (max U 0.0240) and wood-framed exterior walls require R-20+5ci or R-13+10ci (max U 0.0450).
What is the maximum window U-Factor and SHGC in Climate Zone 4A?
For residential construction under 2021 IECC, Zone 4A requires fenestration U-Factor <= 0.30 (tightening to 0.29 under 2024 IECC modeling) with SHGC NR (N/A). NR in EnvelopeCheck residential UA engine (prescriptive IECC 2021 Table R402.1.3 lists 0.40 for 4A; 0.36 commercial).
How does commercial COMcheck differ from residential REScheck in Zone 4A?
Commercial buildings in Zone 4A use steel-framed/mass wall and above-deck roof assemblies (window U <= 0.36, SHGC <= 0.36, roof R-30ci (above deck), wall R-13 + 7.5ci (steel)) and cap prescriptive Window-to-Wall Ratio at 30%.
Explore All 15 IECC Climate Zones
Verify Your Climate Zone 4A Blueprints in Minutes
Upload permit PDFs or CSV schedules to calculate net wall areas, check Zone 4A U-Factor & SHGC compliance, and export DOE REScheck (.rck) or PNNL COMcheck payloads.