IECC CLIMATE ZONE 3B // Warm · Dry
Climate Zone 3B Insulation R-Values, Window U-Factor & SHGC Requirements
Side-by-side IECC 2021 vs 2024 residential REScheck and commercial COMcheck thermal envelope specifications for Climate Zone 3B (Los Angeles, CA, Las Vegas, NV, El Paso, TX, Sacramento, CA, Lubbock, TX).
| Assembly Component | 2021 IECC Residential | 2024 IECC Residential | 2021 COMcheck (Com) | 2024 COMcheck (Com) |
|---|---|---|---|---|
| Fenestration Max U-Factor | 0.30 | 0.29 | 0.42 | 0.40 |
| Glazing Max SHGC | 0.25 | 0.25 | 0.25 | 0.25 |
| Ceiling / Roof R-Value (Max U) | R-49 (0.0260) | R-49 (0.0250) | R-25ci (above deck) (0.0390) | R-25ci (above deck) (0.0374) |
| Exterior Wall R-Value (Max U) | R-20+0 or R-13+5ci (0.0600) | R-20+0 or R-13+5ci (0.0576) | R-13 + 5ci (steel) (0.0770) | R-13 + 5ci (steel) (0.0739) |
| Floor Insulation (Max U) | R-19 (0.0470) | R-19 (0.0451) | U ≤ 0.0740 | U ≤ 0.0710 |
| Basement Wall R-Value | R-5ci or R-13 | R-5ci or R-13 | C402 Below-Grade | C402 Below-Grade |
| Slab Edge R-Value (Max F) | R-10ci (2 ft) (F ≤ 0.54) | R-10ci (2 ft) (F ≤ 0.54) | F ≤ 0.54 | F ≤ 0.54 |
| Opaque Door Max U-Factor | 0.30 | 0.29 | 0.61 | 0.59 |
Warm-dry cooling control: SHGC <= 0.25 (California Title 24 caps warm zones at 0.23).
US States Containing IECC Climate Zone 3B (6)
Arizona (AZ)
2018 / 2021 IECC (Home Rule)
California (CA)
2022 California Title 24 Part 6
Nevada (NV)
2021 IECC (Nevada State Energy Code)
New Mexico (NM)
2021 IECC (2021 NM Energy Conservation Code)
Texas (TX)
2015 / 2021 IECC (SECO Statewide; Austin/Houston/Dallas 2021)
Utah (UT)
2021 IECC (Utah State Construction Code Amended)
Permit & Energy Code FAQ
What are the residential wall and ceiling R-Values for IECC Climate Zone 3B?
Under 2021 IECC in Climate Zone 3B, prescriptive residential ceilings require R-49 (max U 0.0260) and wood-framed exterior walls require R-20+0 or R-13+5ci (max U 0.0600).
What is the maximum window U-Factor and SHGC in Climate Zone 3B?
For residential construction under 2021 IECC, Zone 3B requires fenestration U-Factor <= 0.30 (tightening to 0.29 under 2024 IECC modeling) with SHGC 0.25. Warm-dry cooling control: SHGC <= 0.25 (California Title 24 caps warm zones at 0.23).
How does commercial COMcheck differ from residential REScheck in Zone 3B?
Commercial buildings in Zone 3B use steel-framed/mass wall and above-deck roof assemblies (window U <= 0.42, SHGC <= 0.25, roof R-25ci (above deck), wall R-13 + 5ci (steel)) and cap prescriptive Window-to-Wall Ratio at 30%.