IECC CLIMATE ZONE 7 // Very Cold · All

Climate Zone 7 Insulation R-Values, Window U-Factor & SHGC Requirements

Side-by-side IECC 2021 vs 2024 residential REScheck and commercial COMcheck thermal envelope specifications for Climate Zone 7 (Anchorage, AK, Fargo, ND, Duluth, MN, Grand Forks, ND, Aspen, CO).

IECC 2021 vs 2024 Thermal Envelope Specification Table — Climate Zone 7
Assembly Component2021 IECC Residential2024 IECC Residential2021 COMcheck (Com)2024 COMcheck (Com)
Fenestration Max U-Factor0.300.290.290.28
Glazing Max SHGCNR (N/A)NR (N/A)0.450.45
Ceiling / Roof R-Value (Max U)R-60 (0.0240)R-60 (0.0230)R-35ci (above deck) (0.0280)R-35ci (above deck) (0.0269)
Exterior Wall R-Value (Max U)R-20+5ci or R-13+10ci (0.0450)R-20+5ci or R-13+10ci (0.0432)R-13 + 12.5ci (steel) (0.0490)R-13 + 12.5ci (steel) (0.0470)
Floor Insulation (Max U)R-38 (0.0280)R-38 (0.0269)U ≤ 0.0420U ≤ 0.0403
Basement Wall R-ValueR-15ci or R-19R-15ci or R-19C402 Below-GradeC402 Below-Grade
Slab Edge R-Value (Max F)R-10ci (4 ft) (F ≤ 0.51)R-10ci (4 ft) (F ≤ 0.51)F ≤ 0.43F ≤ 0.43
Opaque Door Max U-Factor0.300.290.370.35
Zone 7 Solar Heat Gain Coefficient (SHGC) Guidance

Very cold heating climate: Residential SHGC is NR (N/A); floor R-38 and high-performance triple glazing are common UA levers.

Representative US Cities in Climate Zone 7
Anchorage, AKFargo, NDDuluth, MNGrand Forks, NDAspen, CO

US States Containing IECC Climate Zone 7 (8)

Permit & Energy Code FAQ

What are the residential wall and ceiling R-Values for IECC Climate Zone 7?

Under 2021 IECC in Climate Zone 7, prescriptive residential ceilings require R-60 (max U 0.0240) and wood-framed exterior walls require R-20+5ci or R-13+10ci (max U 0.0450).

What is the maximum window U-Factor and SHGC in Climate Zone 7?

For residential construction under 2021 IECC, Zone 7 requires fenestration U-Factor <= 0.30 (tightening to 0.29 under 2024 IECC modeling) with SHGC NR (N/A). Very cold heating climate: Residential SHGC is NR (N/A); floor R-38 and high-performance triple glazing are common UA levers.

How does commercial COMcheck differ from residential REScheck in Zone 7?

Commercial buildings in Zone 7 use steel-framed/mass wall and above-deck roof assemblies (window U <= 0.29, SHGC <= 0.45, roof R-35ci (above deck), wall R-13 + 12.5ci (steel)) and cap prescriptive Window-to-Wall Ratio at 30%.

Explore All 15 IECC Climate Zones