IECC CLIMATE ZONE 3A // Warm · Humid

Climate Zone 3A Insulation R-Values, Window U-Factor & SHGC Requirements

Side-by-side IECC 2021 vs 2024 residential REScheck and commercial COMcheck thermal envelope specifications for Climate Zone 3A (Dallas, TX, Atlanta, GA, Charlotte, NC, Charleston, SC, Birmingham, AL).

IECC 2021 vs 2024 Thermal Envelope Specification Table — Climate Zone 3A
Assembly Component2021 IECC Residential2024 IECC Residential2021 COMcheck (Com)2024 COMcheck (Com)
Fenestration Max U-Factor0.300.290.420.40
Glazing Max SHGC0.250.250.250.25
Ceiling / Roof R-Value (Max U)R-49 (0.0260)R-49 (0.0250)R-25ci (above deck) (0.0390)R-25ci (above deck) (0.0374)
Exterior Wall R-Value (Max U)R-20+0 or R-13+5ci (0.0600)R-20+0 or R-13+5ci (0.0576)R-13 + 5ci (steel) (0.0770)R-13 + 5ci (steel) (0.0739)
Floor Insulation (Max U)R-19 (0.0470)R-19 (0.0451)U ≤ 0.0740U ≤ 0.0710
Basement Wall R-ValueR-5ci or R-13R-5ci or R-13C402 Below-GradeC402 Below-Grade
Slab Edge R-Value (Max F)R-10ci (2 ft) (F ≤ 0.54)R-10ci (2 ft) (F ≤ 0.54)F ≤ 0.54F ≤ 0.54
Opaque Door Max U-Factor0.300.290.610.59
Zone 3A Solar Heat Gain Coefficient (SHGC) Guidance

Balanced warm-humid climate: SHGC <= 0.25 and fenestration U-Factor <= 0.30 under 2021 IECC.

Representative US Cities in Climate Zone 3A
Dallas, TXAtlanta, GACharlotte, NCCharleston, SCBirmingham, AL

US States Containing IECC Climate Zone 3A (10)

Permit & Energy Code FAQ

What are the residential wall and ceiling R-Values for IECC Climate Zone 3A?

Under 2021 IECC in Climate Zone 3A, prescriptive residential ceilings require R-49 (max U 0.0260) and wood-framed exterior walls require R-20+0 or R-13+5ci (max U 0.0600).

What is the maximum window U-Factor and SHGC in Climate Zone 3A?

For residential construction under 2021 IECC, Zone 3A requires fenestration U-Factor <= 0.30 (tightening to 0.29 under 2024 IECC modeling) with SHGC 0.25. Balanced warm-humid climate: SHGC <= 0.25 and fenestration U-Factor <= 0.30 under 2021 IECC.

How does commercial COMcheck differ from residential REScheck in Zone 3A?

Commercial buildings in Zone 3A use steel-framed/mass wall and above-deck roof assemblies (window U <= 0.42, SHGC <= 0.25, roof R-25ci (above deck), wall R-13 + 5ci (steel)) and cap prescriptive Window-to-Wall Ratio at 30%.

Explore All 15 IECC Climate Zones

Verify Your Climate Zone 3A Blueprints in Minutes

Upload permit PDFs or CSV schedules to calculate net wall areas, check Zone 3A U-Factor & SHGC compliance, and export DOE REScheck (.rck) or PNNL COMcheck payloads.

Open Takeoff Workbench