NC ENERGY CODE COMPLIANCE // 3A, 4A, 5A

North Carolina Energy Code, IECC Climate Zones & REScheck / COMcheck Guide

Prescriptive building envelope R-Values, maximum fenestration U-Factors, SHGC caps, and blueprint takeoff rules for North Carolina (2018 NC Energy Conservation Code (2015/2018 IECC) / 2018 NC Energy Conservation Code / ASHRAE 90.1).

Adopted Energy Codes & Jurisdiction Summary

Residential Energy Code

2018 NC Energy Conservation Code (2015/2018 IECC)

Commercial Energy Code

2018 NC Energy Conservation Code / ASHRAE 90.1

Representative ZIP

28202 · Climate Zone 3A

DOE REScheck Acceptance

Accepted Statewide (NC Residential / REScheck-Web)

PNNL COMcheck Acceptance

Accepted Statewide (PNNL COMcheck-Web)

Sample Major Cities

Charlotte (3A), Raleigh (4A), Durham (4A), Asheville (4A)

Charlotte and coastal plains are Zone 3A, the Research Triangle (Raleigh/Durham) and Piedmont are Zone 4A, and Avery/Mitchell/Watauga mountains are Zone 5A.

Applicable IECC Climate Zones in North Carolina

Primary Zone (3A) Envelope Specification Targets — 2018 IECC
Envelope ComponentResidential TargetCommercial Target
Fenestration Max U-Factor0.320.45
Glazing Max SHGC0.250.25
Ceiling / Roof Insulation & Max UR-49 (U ≤ 0.0276)R-25ci (above deck) (U ≤ 0.0413)
Above-Grade Wall R-Value & Max UR-20+0 or R-13+5ci (U ≤ 0.0636)R-13 + 5ci (steel) (U ≤ 0.0816)
Floor Insulation & Max UR-19 (U ≤ 0.0498)U ≤ 0.0784
Basement Wall R-ValueR-5ci or R-13ASHRAE 90.1 Table C402
Slab Perimeter R-Value & Max FR-10ci (2 ft) (F ≤ 0.54)F ≤ 0.54
Opaque Door Max U-Factor0.320.65

Blueprint PDF to REScheck (.rck) & COMcheck Workflow

01

Upload Architectural Permit PDF or CAD Schedule

Drop elevations and window/door schedules into EnvelopeCheck. Parent-wall gross areas and opening deductions calculate automatically.

NC · IECC / 90.1
02

Audit Against State Climate Zone & Code Limits

Resolve ZIP-to-climate-zone U-Factor, SHGC, and R-Value limits inline and clear amber missing-parameter diagnostics before city plan check.

NC · IECC / 90.1
03

Export DOE REScheck (.rck) or PNNL COMcheck Bundle

Download clean .rck XML, formula-audited .xlsx workbooks, or PNNL COMcheck JSON plus 1 free Revision 2 Diff when plans change.

NC · IECC / 90.1

Permit & Energy Code FAQ

What residential and commercial energy codes does North Carolina enforce?

North Carolina enforces 2018 NC Energy Conservation Code (2015/2018 IECC) for residential projects and 2018 NC Energy Conservation Code / ASHRAE 90.1 for commercial construction. Charlotte and coastal plains are Zone 3A, the Research Triangle (Raleigh/Durham) and Piedmont are Zone 4A, and Avery/Mitchell/Watauga mountains are Zone 5A.

Which IECC climate zones apply in North Carolina?

North Carolina spans IECC Climate Zone(s) 3A, 4A, 5A, with Zone 3A representing its primary metro baseline (e.g., Charlotte (3A), Raleigh (4A), Durham (4A), Asheville (4A)).

Can I submit DOE REScheck or PNNL COMcheck reports for North Carolina building permits?

Residential status: Accepted Statewide (NC Residential / REScheck-Web). Commercial status: Accepted Statewide (PNNL COMcheck-Web). EnvelopeCheck compiles blueprint PDFs into clean .rck XML and COMcheck JSON payloads to accelerate permit filing.

Automate Your North Carolina Permit Envelope Takeoff

Stop manually re-keying North Carolina window and wall schedules. Preview your Climate Zone 3A UA margin and first 5 assemblies free with zero login.

Open Takeoff Workbench
North Carolina Energy Code (2018 NC Energy Conservation Code (2015/2018 IECC)) — R-Value, Climate Zones & REScheck Guide | EnvelopeCheck