IECC CLIMATE ZONE 1A // Very Hot · Humid
Climate Zone 1A Insulation R-Values, Window U-Factor & SHGC Requirements
Side-by-side IECC 2021 vs 2024 residential REScheck and commercial COMcheck thermal envelope specifications for Climate Zone 1A (Miami, FL, Fort Lauderdale, FL, Key West, FL, Honolulu, HI).
| Assembly Component | 2021 IECC Residential | 2024 IECC Residential | 2021 COMcheck (Com) | 2024 COMcheck (Com) |
|---|---|---|---|---|
| Fenestration Max U-Factor | 0.50 | 0.48 | 0.50 | 0.48 |
| Glazing Max SHGC | 0.25 | 0.25 | 0.23 | 0.23 |
| Ceiling / Roof R-Value (Max U) | R-30 (0.0350) | R-30 (0.0336) | R-20ci (above deck) (0.0480) | R-20ci (above deck) (0.0461) |
| Exterior Wall R-Value (Max U) | R-13+0 (0.0840) | R-13+0 (0.0806) | R-13 + 0ci (steel) (0.1240) | R-13 + 0ci (steel) (0.1190) |
| Floor Insulation (Max U) | R-13 (0.0640) | R-13 (0.0614) | U ≤ 0.1070 | U ≤ 0.1027 |
| Basement Wall R-Value | R-0 (NR) | R-0 (NR) | C402 Below-Grade | C402 Below-Grade |
| Slab Edge R-Value (Max F) | R-0 (NR) (F ≤ 0.73) | R-0 (NR) (F ≤ 0.73) | F ≤ 0.73 | F ≤ 0.73 |
| Opaque Door Max U-Factor | 0.50 | 0.48 | 0.61 | 0.59 |
Strict cooling-dominated solar control: max SHGC 0.25 residential (0.23 commercial).
US States Containing IECC Climate Zone 1A (2)
Permit & Energy Code FAQ
What are the residential wall and ceiling R-Values for IECC Climate Zone 1A?
Under 2021 IECC in Climate Zone 1A, prescriptive residential ceilings require R-30 (max U 0.0350) and wood-framed exterior walls require R-13+0 (max U 0.0840).
What is the maximum window U-Factor and SHGC in Climate Zone 1A?
For residential construction under 2021 IECC, Zone 1A requires fenestration U-Factor <= 0.50 (tightening to 0.48 under 2024 IECC modeling) with SHGC 0.25. Strict cooling-dominated solar control: max SHGC 0.25 residential (0.23 commercial).
How does commercial COMcheck differ from residential REScheck in Zone 1A?
Commercial buildings in Zone 1A use steel-framed/mass wall and above-deck roof assemblies (window U <= 0.50, SHGC <= 0.23, roof R-20ci (above deck), wall R-13 + 0ci (steel)) and cap prescriptive Window-to-Wall Ratio at 30%.
Explore All 15 IECC Climate Zones
Verify Your Climate Zone 1A Blueprints in Minutes
Upload permit PDFs or CSV schedules to calculate net wall areas, check Zone 1A U-Factor & SHGC compliance, and export DOE REScheck (.rck) or PNNL COMcheck payloads.