FL ENERGY CODE COMPLIANCE // 1A, 2A

Florida Energy Code, IECC Climate Zones & REScheck / COMcheck Guide

Prescriptive building envelope R-Values, maximum fenestration U-Factors, SHGC caps, and blueprint takeoff rules for Florida (8th Edition (2023) Florida Building Code – Energy (2021 IECC base) / 8th Edition (2023) FBC Energy / ASHRAE 90.1-2019).

Adopted Energy Codes & Jurisdiction Summary

Residential Energy Code

8th Edition (2023) Florida Building Code – Energy (2021 IECC base)

Commercial Energy Code

8th Edition (2023) FBC Energy / ASHRAE 90.1-2019

Representative ZIP

33101 · Climate Zone 2A

DOE REScheck Acceptance

Envelope Pre-Check (FBC EnergyGauge / REScheck)

PNNL COMcheck Acceptance

Accepted (COMcheck-Web / FBC Energy)

Sample Major Cities

Miami (1A), Tampa (2A), Orlando (2A), Jacksonville (2A)

South Florida (Miami-Dade, Broward, Monroe) is Zone 1A while Central and North Florida are Zone 2A; impact glazing SHGC <= 0.25 is critical.

Applicable IECC Climate Zones in Florida

Primary Zone (2A) Envelope Specification Targets — 2021 IECC
Envelope ComponentResidential TargetCommercial Target
Fenestration Max U-Factor0.400.45
Glazing Max SHGC0.250.25
Ceiling / Roof Insulation & Max UR-49 (U ≤ 0.0260)R-25ci (above deck) (U ≤ 0.0390)
Above-Grade Wall R-Value & Max UR-13+0 (U ≤ 0.0840)R-13 + 3.8ci (steel) (U ≤ 0.0840)
Floor Insulation & Max UR-13 (U ≤ 0.0640)U ≤ 0.0740
Basement Wall R-ValueR-0 (NR)ASHRAE 90.1 Table C402
Slab Perimeter R-Value & Max FR-0 (NR) (F ≤ 0.73)F ≤ 0.73
Opaque Door Max U-Factor0.400.61

Blueprint PDF to REScheck (.rck) & COMcheck Workflow

01

Upload Architectural Permit PDF or CAD Schedule

Drop elevations and window/door schedules into EnvelopeCheck. Parent-wall gross areas and opening deductions calculate automatically.

FL · IECC / 90.1
02

Audit Against State Climate Zone & Code Limits

Resolve ZIP-to-climate-zone U-Factor, SHGC, and R-Value limits inline and clear amber missing-parameter diagnostics before city plan check.

FL · IECC / 90.1
03

Export DOE REScheck (.rck) or PNNL COMcheck Bundle

Download clean .rck XML, formula-audited .xlsx workbooks, or PNNL COMcheck JSON plus 1 free Revision 2 Diff when plans change.

FL · IECC / 90.1

Permit & Energy Code FAQ

What residential and commercial energy codes does Florida enforce?

Florida enforces 8th Edition (2023) Florida Building Code – Energy (2021 IECC base) for residential projects and 8th Edition (2023) FBC Energy / ASHRAE 90.1-2019 for commercial construction. South Florida (Miami-Dade, Broward, Monroe) is Zone 1A while Central and North Florida are Zone 2A; impact glazing SHGC <= 0.25 is critical.

Which IECC climate zones apply in Florida?

Florida spans IECC Climate Zone(s) 1A, 2A, with Zone 2A representing its primary metro baseline (e.g., Miami (1A), Tampa (2A), Orlando (2A), Jacksonville (2A)).

Can I submit DOE REScheck or PNNL COMcheck reports for Florida building permits?

Residential status: Envelope Pre-Check (FBC EnergyGauge / REScheck). Commercial status: Accepted (COMcheck-Web / FBC Energy). EnvelopeCheck compiles blueprint PDFs into clean .rck XML and COMcheck JSON payloads to accelerate permit filing.

Automate Your Florida Permit Envelope Takeoff

Stop manually re-keying Florida window and wall schedules. Preview your Climate Zone 2A UA margin and first 5 assemblies free with zero login.

Open Takeoff Workbench
Florida Energy Code (8th Edition (2023) Florida Building Code – Energy (2021 IECC base)) — R-Value, Climate Zones & REScheck Guide | EnvelopeCheck