FL ENERGY CODE COMPLIANCE // 1A, 2A
Florida Energy Code, IECC Climate Zones & REScheck / COMcheck Guide
Prescriptive building envelope R-Values, maximum fenestration U-Factors, SHGC caps, and blueprint takeoff rules for Florida (8th Edition (2023) Florida Building Code – Energy (2021 IECC base) / 8th Edition (2023) FBC Energy / ASHRAE 90.1-2019).
Residential Energy Code
8th Edition (2023) Florida Building Code – Energy (2021 IECC base)
Commercial Energy Code
8th Edition (2023) FBC Energy / ASHRAE 90.1-2019
Representative ZIP
33101 · Climate Zone 2A
DOE REScheck Acceptance
Envelope Pre-Check (FBC EnergyGauge / REScheck)
PNNL COMcheck Acceptance
Accepted (COMcheck-Web / FBC Energy)
Sample Major Cities
Miami (1A), Tampa (2A), Orlando (2A), Jacksonville (2A)
Applicable IECC Climate Zones in Florida
| Envelope Component | Residential Target | Commercial Target |
|---|---|---|
| Fenestration Max U-Factor | 0.40 | 0.45 |
| Glazing Max SHGC | 0.25 | 0.25 |
| Ceiling / Roof Insulation & Max U | R-49 (U ≤ 0.0260) | R-25ci (above deck) (U ≤ 0.0390) |
| Above-Grade Wall R-Value & Max U | R-13+0 (U ≤ 0.0840) | R-13 + 3.8ci (steel) (U ≤ 0.0840) |
| Floor Insulation & Max U | R-13 (U ≤ 0.0640) | U ≤ 0.0740 |
| Basement Wall R-Value | R-0 (NR) | ASHRAE 90.1 Table C402 |
| Slab Perimeter R-Value & Max F | R-0 (NR) (F ≤ 0.73) | F ≤ 0.73 |
| Opaque Door Max U-Factor | 0.40 | 0.61 |
Blueprint PDF to REScheck (.rck) & COMcheck Workflow
Upload Architectural Permit PDF or CAD Schedule
Drop elevations and window/door schedules into EnvelopeCheck. Parent-wall gross areas and opening deductions calculate automatically.
Audit Against State Climate Zone & Code Limits
Resolve ZIP-to-climate-zone U-Factor, SHGC, and R-Value limits inline and clear amber missing-parameter diagnostics before city plan check.
Export DOE REScheck (.rck) or PNNL COMcheck Bundle
Download clean .rck XML, formula-audited .xlsx workbooks, or PNNL COMcheck JSON plus 1 free Revision 2 Diff when plans change.
Permit & Energy Code FAQ
What residential and commercial energy codes does Florida enforce?
Florida enforces 8th Edition (2023) Florida Building Code – Energy (2021 IECC base) for residential projects and 8th Edition (2023) FBC Energy / ASHRAE 90.1-2019 for commercial construction. South Florida (Miami-Dade, Broward, Monroe) is Zone 1A while Central and North Florida are Zone 2A; impact glazing SHGC <= 0.25 is critical.
Which IECC climate zones apply in Florida?
Florida spans IECC Climate Zone(s) 1A, 2A, with Zone 2A representing its primary metro baseline (e.g., Miami (1A), Tampa (2A), Orlando (2A), Jacksonville (2A)).
Can I submit DOE REScheck or PNNL COMcheck reports for Florida building permits?
Residential status: Envelope Pre-Check (FBC EnergyGauge / REScheck). Commercial status: Accepted (COMcheck-Web / FBC Energy). EnvelopeCheck compiles blueprint PDFs into clean .rck XML and COMcheck JSON payloads to accelerate permit filing.
Automate Your Florida Permit Envelope Takeoff
Stop manually re-keying Florida window and wall schedules. Preview your Climate Zone 2A UA margin and first 5 assemblies free with zero login.