IECC CLIMATE ZONE 2A // Hot · Humid

Climate Zone 2A Insulation R-Values, Window U-Factor & SHGC Requirements

Side-by-side IECC 2021 vs 2024 residential REScheck and commercial COMcheck thermal envelope specifications for Climate Zone 2A (Austin, TX, Houston, TX, San Antonio, TX, Tampa, FL, New Orleans, LA).

IECC 2021 vs 2024 Thermal Envelope Specification Table — Climate Zone 2A
Assembly Component2021 IECC Residential2024 IECC Residential2021 COMcheck (Com)2024 COMcheck (Com)
Fenestration Max U-Factor0.400.380.450.43
Glazing Max SHGC0.250.250.250.25
Ceiling / Roof R-Value (Max U)R-49 (0.0260)R-49 (0.0250)R-25ci (above deck) (0.0390)R-25ci (above deck) (0.0374)
Exterior Wall R-Value (Max U)R-13+0 (0.0840)R-13+0 (0.0806)R-13 + 3.8ci (steel) (0.0840)R-13 + 3.8ci (steel) (0.0806)
Floor Insulation (Max U)R-13 (0.0640)R-13 (0.0614)U ≤ 0.0740U ≤ 0.0710
Basement Wall R-ValueR-0 (NR)R-0 (NR)C402 Below-GradeC402 Below-Grade
Slab Edge R-Value (Max F)R-0 (NR) (F ≤ 0.73)R-0 (NR) (F ≤ 0.73)F ≤ 0.73F ≤ 0.73
Opaque Door Max U-Factor0.400.380.610.59
Zone 2A Solar Heat Gain Coefficient (SHGC) Guidance

Cooling-dominated humid climate: max SHGC 0.25 residential and commercial.

Representative US Cities in Climate Zone 2A
Austin, TXHouston, TXSan Antonio, TXTampa, FLNew Orleans, LA

US States Containing IECC Climate Zone 2A (6)

Permit & Energy Code FAQ

What are the residential wall and ceiling R-Values for IECC Climate Zone 2A?

Under 2021 IECC in Climate Zone 2A, prescriptive residential ceilings require R-49 (max U 0.0260) and wood-framed exterior walls require R-13+0 (max U 0.0840).

What is the maximum window U-Factor and SHGC in Climate Zone 2A?

For residential construction under 2021 IECC, Zone 2A requires fenestration U-Factor <= 0.40 (tightening to 0.38 under 2024 IECC modeling) with SHGC 0.25. Cooling-dominated humid climate: max SHGC 0.25 residential and commercial.

How does commercial COMcheck differ from residential REScheck in Zone 2A?

Commercial buildings in Zone 2A use steel-framed/mass wall and above-deck roof assemblies (window U <= 0.45, SHGC <= 0.25, roof R-25ci (above deck), wall R-13 + 3.8ci (steel)) and cap prescriptive Window-to-Wall Ratio at 30%.

Explore All 15 IECC Climate Zones