IECC CLIMATE ZONE 6A // Cold · Humid

Climate Zone 6A Insulation R-Values, Window U-Factor & SHGC Requirements

Side-by-side IECC 2021 vs 2024 residential REScheck and commercial COMcheck thermal envelope specifications for Climate Zone 6A (Minneapolis, MN, Milwaukee, WI, Burlington, VT, Portland, ME, Sioux Falls, SD).

IECC 2021 vs 2024 Thermal Envelope Specification Table — Climate Zone 6A
Assembly Component2021 IECC Residential2024 IECC Residential2021 COMcheck (Com)2024 COMcheck (Com)
Fenestration Max U-Factor0.300.290.340.33
Glazing Max SHGCNR (N/A)NR (N/A)0.400.40
Ceiling / Roof R-Value (Max U)R-60 (0.0240)R-60 (0.0230)R-30ci (above deck) (0.0320)R-30ci (above deck) (0.0307)
Exterior Wall R-Value (Max U)R-20+5ci or R-13+10ci (0.0450)R-20+5ci or R-13+10ci (0.0432)R-13 + 12.5ci (steel) (0.0490)R-13 + 12.5ci (steel) (0.0470)
Floor Insulation (Max U)R-30 (0.0330)R-30 (0.0317)U ≤ 0.0510U ≤ 0.0490
Basement Wall R-ValueR-15ci or R-19R-15ci or R-19C402 Below-GradeC402 Below-Grade
Slab Edge R-Value (Max F)R-10ci (4 ft) (F ≤ 0.51)R-10ci (4 ft) (F ≤ 0.51)F ≤ 0.51F ≤ 0.51
Opaque Door Max U-Factor0.300.290.370.35
Zone 6A Solar Heat Gain Coefficient (SHGC) Guidance

Cold heating-dominated: Residential SHGC is NR (N/A); continuous exterior wall insulation (R-20+5ci / R-13+10ci) drives UA compliance.

Representative US Cities in Climate Zone 6A
Minneapolis, MNMilwaukee, WIBurlington, VTPortland, MESioux Falls, SD

US States Containing IECC Climate Zone 6A (10)

Permit & Energy Code FAQ

What are the residential wall and ceiling R-Values for IECC Climate Zone 6A?

Under 2021 IECC in Climate Zone 6A, prescriptive residential ceilings require R-60 (max U 0.0240) and wood-framed exterior walls require R-20+5ci or R-13+10ci (max U 0.0450).

What is the maximum window U-Factor and SHGC in Climate Zone 6A?

For residential construction under 2021 IECC, Zone 6A requires fenestration U-Factor <= 0.30 (tightening to 0.29 under 2024 IECC modeling) with SHGC NR (N/A). Cold heating-dominated: Residential SHGC is NR (N/A); continuous exterior wall insulation (R-20+5ci / R-13+10ci) drives UA compliance.

How does commercial COMcheck differ from residential REScheck in Zone 6A?

Commercial buildings in Zone 6A use steel-framed/mass wall and above-deck roof assemblies (window U <= 0.34, SHGC <= 0.40, roof R-30ci (above deck), wall R-13 + 12.5ci (steel)) and cap prescriptive Window-to-Wall Ratio at 30%.

Explore All 15 IECC Climate Zones