DC ENERGY CODE COMPLIANCE // 4A
District of Columbia Energy Code, IECC Climate Zones & REScheck / COMcheck Guide
Prescriptive building envelope R-Values, maximum fenestration U-Factors, SHGC caps, and blueprint takeoff rules for District of Columbia (2021 IECC / DC Energy Conservation Code / 2021 IECC / ASHRAE 90.1-2019 (DC Amended)).
Residential Energy Code
2021 IECC / DC Energy Conservation Code
Commercial Energy Code
2021 IECC / ASHRAE 90.1-2019 (DC Amended)
Representative ZIP
20001 · Climate Zone 4A
DOE REScheck Acceptance
Accepted by DC DOB (REScheck-Web)
PNNL COMcheck Acceptance
Accepted by DC DOB (COMcheck-Web)
Sample Major Cities
Washington, DC (4A), Georgetown (4A), Capitol Hill (4A)
Applicable IECC Climate Zones in District of Columbia
| Envelope Component | Residential Target | Commercial Target |
|---|---|---|
| Fenestration Max U-Factor | 0.30 | 0.36 |
| Glazing Max SHGC | NR (N/A) | 0.36 |
| Ceiling / Roof Insulation & Max U | R-60 (U ≤ 0.0240) | R-30ci (above deck) (U ≤ 0.0320) |
| Above-Grade Wall R-Value & Max U | R-20+5ci or R-13+10ci (U ≤ 0.0450) | R-13 + 7.5ci (steel) (U ≤ 0.0640) |
| Floor Insulation & Max U | R-19 (U ≤ 0.0470) | U ≤ 0.0520 |
| Basement Wall R-Value | R-10ci or R-13 | ASHRAE 90.1 Table C402 |
| Slab Perimeter R-Value & Max F | R-10ci (4 ft) (F ≤ 0.52) | F ≤ 0.52 |
| Opaque Door Max U-Factor | 0.30 | 0.37 |
Blueprint PDF to REScheck (.rck) & COMcheck Workflow
Upload Architectural Permit PDF or CAD Schedule
Drop elevations and window/door schedules into EnvelopeCheck. Parent-wall gross areas and opening deductions calculate automatically.
Audit Against State Climate Zone & Code Limits
Resolve ZIP-to-climate-zone U-Factor, SHGC, and R-Value limits inline and clear amber missing-parameter diagnostics before city plan check.
Export DOE REScheck (.rck) or PNNL COMcheck Bundle
Download clean .rck XML, formula-audited .xlsx workbooks, or PNNL COMcheck JSON plus 1 free Revision 2 Diff when plans change.
Permit & Energy Code FAQ
What residential and commercial energy codes does District of Columbia enforce?
District of Columbia enforces 2021 IECC / DC Energy Conservation Code for residential projects and 2021 IECC / ASHRAE 90.1-2019 (DC Amended) for commercial construction. DC Department of Buildings (DOB) enforces strict Zone 4A envelope limits and continuous insulation verification on townhome renovations and commercial TI.
Which IECC climate zones apply in District of Columbia?
District of Columbia spans IECC Climate Zone(s) 4A, with Zone 4A representing its primary metro baseline (e.g., Washington, DC (4A), Georgetown (4A), Capitol Hill (4A)).
Can I submit DOE REScheck or PNNL COMcheck reports for District of Columbia building permits?
Residential status: Accepted by DC DOB (REScheck-Web). Commercial status: Accepted by DC DOB (COMcheck-Web). EnvelopeCheck compiles blueprint PDFs into clean .rck XML and COMcheck JSON payloads to accelerate permit filing.