DC ENERGY CODE COMPLIANCE // 4A

District of Columbia Energy Code, IECC Climate Zones & REScheck / COMcheck Guide

Prescriptive building envelope R-Values, maximum fenestration U-Factors, SHGC caps, and blueprint takeoff rules for District of Columbia (2021 IECC / DC Energy Conservation Code / 2021 IECC / ASHRAE 90.1-2019 (DC Amended)).

Adopted Energy Codes & Jurisdiction Summary

Residential Energy Code

2021 IECC / DC Energy Conservation Code

Commercial Energy Code

2021 IECC / ASHRAE 90.1-2019 (DC Amended)

Representative ZIP

20001 · Climate Zone 4A

DOE REScheck Acceptance

Accepted by DC DOB (REScheck-Web)

PNNL COMcheck Acceptance

Accepted by DC DOB (COMcheck-Web)

Sample Major Cities

Washington, DC (4A), Georgetown (4A), Capitol Hill (4A)

DC Department of Buildings (DOB) enforces strict Zone 4A envelope limits and continuous insulation verification on townhome renovations and commercial TI.

Applicable IECC Climate Zones in District of Columbia

Primary Zone (4A) Envelope Specification Targets — 2021 IECC
Envelope ComponentResidential TargetCommercial Target
Fenestration Max U-Factor0.300.36
Glazing Max SHGCNR (N/A)0.36
Ceiling / Roof Insulation & Max UR-60 (U ≤ 0.0240)R-30ci (above deck) (U ≤ 0.0320)
Above-Grade Wall R-Value & Max UR-20+5ci or R-13+10ci (U ≤ 0.0450)R-13 + 7.5ci (steel) (U ≤ 0.0640)
Floor Insulation & Max UR-19 (U ≤ 0.0470)U ≤ 0.0520
Basement Wall R-ValueR-10ci or R-13ASHRAE 90.1 Table C402
Slab Perimeter R-Value & Max FR-10ci (4 ft) (F ≤ 0.52)F ≤ 0.52
Opaque Door Max U-Factor0.300.37

Blueprint PDF to REScheck (.rck) & COMcheck Workflow

01

Upload Architectural Permit PDF or CAD Schedule

Drop elevations and window/door schedules into EnvelopeCheck. Parent-wall gross areas and opening deductions calculate automatically.

DC · IECC / 90.1
02

Audit Against State Climate Zone & Code Limits

Resolve ZIP-to-climate-zone U-Factor, SHGC, and R-Value limits inline and clear amber missing-parameter diagnostics before city plan check.

DC · IECC / 90.1
03

Export DOE REScheck (.rck) or PNNL COMcheck Bundle

Download clean .rck XML, formula-audited .xlsx workbooks, or PNNL COMcheck JSON plus 1 free Revision 2 Diff when plans change.

DC · IECC / 90.1

Permit & Energy Code FAQ

What residential and commercial energy codes does District of Columbia enforce?

District of Columbia enforces 2021 IECC / DC Energy Conservation Code for residential projects and 2021 IECC / ASHRAE 90.1-2019 (DC Amended) for commercial construction. DC Department of Buildings (DOB) enforces strict Zone 4A envelope limits and continuous insulation verification on townhome renovations and commercial TI.

Which IECC climate zones apply in District of Columbia?

District of Columbia spans IECC Climate Zone(s) 4A, with Zone 4A representing its primary metro baseline (e.g., Washington, DC (4A), Georgetown (4A), Capitol Hill (4A)).

Can I submit DOE REScheck or PNNL COMcheck reports for District of Columbia building permits?

Residential status: Accepted by DC DOB (REScheck-Web). Commercial status: Accepted by DC DOB (COMcheck-Web). EnvelopeCheck compiles blueprint PDFs into clean .rck XML and COMcheck JSON payloads to accelerate permit filing.

Automate Your District of Columbia Permit Envelope Takeoff

Stop manually re-keying District of Columbia window and wall schedules. Preview your Climate Zone 4A UA margin and first 5 assemblies free with zero login.

Open Takeoff Workbench
District of Columbia Energy Code (2021 IECC / DC Energy Conservation Code) — R-Value, Climate Zones & REScheck Guide | EnvelopeCheck