MA ENERGY CODE COMPLIANCE // 5A

Massachusetts Energy Code, IECC Climate Zones & REScheck / COMcheck Guide

Prescriptive building envelope R-Values, maximum fenestration U-Factors, SHGC caps, and blueprint takeoff rules for Massachusetts (2021 IECC / MA Stretch & Specialized Opt-in Code / 2021 IECC / ASHRAE 90.1-2019 (MA Stretch)).

Adopted Energy Codes & Jurisdiction Summary

Residential Energy Code

2021 IECC / MA Stretch & Specialized Opt-in Code

Commercial Energy Code

2021 IECC / ASHRAE 90.1-2019 (MA Stretch)

Representative ZIP

02108 · Climate Zone 5A

DOE REScheck Acceptance

Accepted for Base Code & Envelope Tradeoff Pre-Check

PNNL COMcheck Acceptance

Accepted (COMcheck-Web / MA Stretch Envelope Check)

Sample Major Cities

Boston (5A), Worcester (5A), Cambridge (5A), Springfield (5A)

All Massachusetts municipalities are Zone 5A; check whether the local town enforces the MA Stretch Code (tighter UA / HERS requirements).

Applicable IECC Climate Zones in Massachusetts

Primary Zone (5A) Envelope Specification Targets — 2021 IECC
Envelope ComponentResidential TargetCommercial Target
Fenestration Max U-Factor0.300.36
Glazing Max SHGCNR (N/A)0.38
Ceiling / Roof Insulation & Max UR-60 (U ≤ 0.0240)R-30ci (above deck) (U ≤ 0.0320)
Above-Grade Wall R-Value & Max UR-20+5ci or R-13+10ci (U ≤ 0.0450)R-13 + 10ci (steel) (U ≤ 0.0550)
Floor Insulation & Max UR-30 (U ≤ 0.0330)U ≤ 0.0520
Basement Wall R-ValueR-15ci or R-19ASHRAE 90.1 Table C402
Slab Perimeter R-Value & Max FR-10ci (4 ft) (F ≤ 0.51)F ≤ 0.51
Opaque Door Max U-Factor0.300.37

Blueprint PDF to REScheck (.rck) & COMcheck Workflow

01

Upload Architectural Permit PDF or CAD Schedule

Drop elevations and window/door schedules into EnvelopeCheck. Parent-wall gross areas and opening deductions calculate automatically.

MA · IECC / 90.1
02

Audit Against State Climate Zone & Code Limits

Resolve ZIP-to-climate-zone U-Factor, SHGC, and R-Value limits inline and clear amber missing-parameter diagnostics before city plan check.

MA · IECC / 90.1
03

Export DOE REScheck (.rck) or PNNL COMcheck Bundle

Download clean .rck XML, formula-audited .xlsx workbooks, or PNNL COMcheck JSON plus 1 free Revision 2 Diff when plans change.

MA · IECC / 90.1

Permit & Energy Code FAQ

What residential and commercial energy codes does Massachusetts enforce?

Massachusetts enforces 2021 IECC / MA Stretch & Specialized Opt-in Code for residential projects and 2021 IECC / ASHRAE 90.1-2019 (MA Stretch) for commercial construction. All Massachusetts municipalities are Zone 5A; check whether the local town enforces the MA Stretch Code (tighter UA / HERS requirements).

Which IECC climate zones apply in Massachusetts?

Massachusetts spans IECC Climate Zone(s) 5A, with Zone 5A representing its primary metro baseline (e.g., Boston (5A), Worcester (5A), Cambridge (5A), Springfield (5A)).

Can I submit DOE REScheck or PNNL COMcheck reports for Massachusetts building permits?

Residential status: Accepted for Base Code & Envelope Tradeoff Pre-Check. Commercial status: Accepted (COMcheck-Web / MA Stretch Envelope Check). EnvelopeCheck compiles blueprint PDFs into clean .rck XML and COMcheck JSON payloads to accelerate permit filing.

Automate Your Massachusetts Permit Envelope Takeoff

Stop manually re-keying Massachusetts window and wall schedules. Preview your Climate Zone 5A UA margin and first 5 assemblies free with zero login.

Open Takeoff Workbench
Massachusetts Energy Code (2021 IECC / MA Stretch & Specialized Opt-in Code) — R-Value, Climate Zones & REScheck Guide | EnvelopeCheck