WA ENERGY CODE COMPLIANCE // 4C, 5B

Washington Energy Code, IECC Climate Zones & REScheck / COMcheck Guide

Prescriptive building envelope R-Values, maximum fenestration U-Factors, SHGC caps, and blueprint takeoff rules for Washington (2021 Washington State Energy Code (WSEC-R) / 2021 Washington State Energy Code (WSEC-C)).

Adopted Energy Codes & Jurisdiction Summary

Residential Energy Code

2021 Washington State Energy Code (WSEC-R)

Commercial Energy Code

2021 Washington State Energy Code (WSEC-C)

Representative ZIP

98101 · Climate Zone 4C

DOE REScheck Acceptance

Envelope Pre-Check (WSEC Credit Form + UA Audit)

PNNL COMcheck Acceptance

Accepted (WSEC-C Envelope / PNNL COMcheck Pre-Check)

Sample Major Cities

Seattle (4C), Tacoma (4C), Bellevue (4C), Spokane (5B)

WSEC 2021 is one of the strictest US codes (window U <= 0.28 residential / 0.32 commercial); Western WA is Marine Zone 4C while Eastern WA (Spokane/Yakima) is Zone 5B.

Applicable IECC Climate Zones in Washington

Primary Zone (4C) Envelope Specification Targets — Washington State Energy Code (WSEC 2021)
Envelope ComponentResidential TargetCommercial Target
Fenestration Max U-Factor0.280.32
Glazing Max SHGCNR (N/A)0.36
Ceiling / Roof Insulation & Max UR-60 (U ≤ 0.0221)R-30ci (above deck) (U ≤ 0.0294)
Above-Grade Wall R-Value & Max UR-20+5ci or R-13+10ci (U ≤ 0.0414)R-13 + 7.5ci (steel) (U ≤ 0.0520)
Floor Insulation & Max UR-30 (U ≤ 0.0432)U ≤ 0.0478
Basement Wall R-ValueR-15ci or R-19ASHRAE 90.1 Table C402
Slab Perimeter R-Value & Max FR-10ci (4 ft) (F ≤ 0.52)F ≤ 0.52
Opaque Door Max U-Factor0.280.34

Blueprint PDF to REScheck (.rck) & COMcheck Workflow

01

Upload Architectural Permit PDF or CAD Schedule

Drop elevations and window/door schedules into EnvelopeCheck. Parent-wall gross areas and opening deductions calculate automatically.

WA · IECC / 90.1
02

Audit Against State Climate Zone & Code Limits

Resolve ZIP-to-climate-zone U-Factor, SHGC, and R-Value limits inline and clear amber missing-parameter diagnostics before city plan check.

WA · IECC / 90.1
03

Export DOE REScheck (.rck) or PNNL COMcheck Bundle

Download clean .rck XML, formula-audited .xlsx workbooks, or PNNL COMcheck JSON plus 1 free Revision 2 Diff when plans change.

WA · IECC / 90.1

Permit & Energy Code FAQ

What residential and commercial energy codes does Washington enforce?

Washington enforces 2021 Washington State Energy Code (WSEC-R) for residential projects and 2021 Washington State Energy Code (WSEC-C) for commercial construction. WSEC 2021 is one of the strictest US codes (window U <= 0.28 residential / 0.32 commercial); Western WA is Marine Zone 4C while Eastern WA (Spokane/Yakima) is Zone 5B.

Which IECC climate zones apply in Washington?

Washington spans IECC Climate Zone(s) 4C, 5B, with Zone 4C representing its primary metro baseline (e.g., Seattle (4C), Tacoma (4C), Bellevue (4C), Spokane (5B)).

Can I submit DOE REScheck or PNNL COMcheck reports for Washington building permits?

Residential status: Envelope Pre-Check (WSEC Credit Form + UA Audit). Commercial status: Accepted (WSEC-C Envelope / PNNL COMcheck Pre-Check). EnvelopeCheck compiles blueprint PDFs into clean .rck XML and COMcheck JSON payloads to accelerate permit filing.

Automate Your Washington Permit Envelope Takeoff

Stop manually re-keying Washington window and wall schedules. Preview your Climate Zone 4C UA margin and first 5 assemblies free with zero login.

Open Takeoff Workbench
Washington Energy Code (2021 Washington State Energy Code (WSEC-R)) — R-Value, Climate Zones & REScheck Guide | EnvelopeCheck